A single-door mechanism that provides complete entry and exit control via connected Access Readers.
Dimensions
174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Input Terminals
(2) Door exit request (1) Door position (1) Emergency
Power Method
PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
UniFi Application Suite
Access
Enclosure Material
Polycarbonate
Mount Material
Polycarbonate
Mounting
DIN-rail (Included)
Indoor and Outdoor Use
Indoor only
Ambient Operating Temperature
0 to 40° C (32 to 104° F)
Ambient Operating Humidity
5 to 95% noncondensing
Networking Interface
(5) 10/100/1000 Base-T
PoE Interface
(1) PoE++ input, 50V DC, 1A (4) PoE outputs, 50V DC, 15.4W per port (Max. 28W aggregated)
Max. Power Consumption
30W (Without PoE output) 50W (With PoE output)
Digital Input
Request to exit, request to enter, remote release, door position sensor
Dry Output Relay
Lock: 30V DC, 1A Aux: 30V DC, 1A
Powered Output Relay
Lock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
Buttons
(1) Factory-reset
Recommend Max. Cable Length
UA-Lock-Electric (400mA)
24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)
24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)
24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)
24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade